久久久影院,五月婷婷色77,久久亚洲电影精品,欧美另类一区二区三区在线

產(chǎn)品展示
PRODUCT DISPLAY

打印當(dāng)前頁

免費(fèi)咨詢:021-67610176

發(fā)郵件給我們:market@hsiyen.cn

分享到:
產(chǎn)品展示您現(xiàn)在的位置: 首頁 > 產(chǎn)品展示 > > 美國戴安Dionex > 美國戴安 P/N: 075399美國戴安Dionex IonPac AS20 Column 陰離子交換色譜柱

美國戴安Dionex IonPac AS20 Column 陰離子交換色譜柱

簡要描述:

戴安公司生產(chǎn)的儀器主要有離子色譜儀、高效液相色譜儀、快速溶劑萃取儀和氨基酸直接分析儀。其中離子色譜儀憑借著雄厚的技術(shù)優(yōu)勢和方法已廣泛地應(yīng)用于各個(gè)領(lǐng)域,其*達(dá)80%。與離子色譜相關(guān)的文章有90%均出自戴安公司生產(chǎn)的離子色譜儀。

型號(hào) 美國戴安 P/N: 075399
廠商性質(zhì) 代理商
更新日期 2018-04-24

IonPac AS20 Hydroxide-Selective Anion-Exchange Column

For Determination of Trace Perchlorate Using Suppressed Conductivity Detection

The IonPac? AS20 hydroxide-selective anion-exchange column is specifically designed for determination of trace concentrations of perchlorate in drinking water, surface water, and groundwater matrices. The capacity and selectivity of the AS20 ensures that perchlorate can be quantified at low μg/L concentrations using suppressed conductivity detection, even in the presence of very high concentrations of chloride, carbonate, and sulfate. The new IonPac AS20 Capillary Column is packed with the same material as the equivalent standard bore version (providing the same performance as a 4 mm column) but requires only 1/100th the eluent flow rate. The capillary format provides the advantage of significantly reduced eluent consumption, which helps reduce operating costs.

  • Recommended for US EPA Method 314.1 (Confirmatory Method)
  • High capacity: 310 μeq per column. (4 × 250 mm)
  • Use the Cryptand C1 Concentrator Column for sample preconcentration with the analytical column
  • Simplified Reagent-Free IC operation provided by the Eluent Generator
  • ASRS 300 or ACES 300 provides RFIC operation with low background and enhanced analyte sensitivity
  • Column selectivity is optimized for 30 °C operating temperature
  • Compatible with organic solvents

The IonPac AS20 is the specified column in US EPA Method 314.1 (Confirmatory Method). The Cryptand C1 Concentrator Column is the specified concentrator column for sample preconcentration in that method.

Use the IonPac AS20 column with an RFIC? system for optimum detection limits. Use the Anion Self-Regenerating Suppressor (ASRS? 300) or the Anion Capillary Electrolytic Suppressor (ACES 300) with the AS20 column for eluent suppression.


IonPac AS20 Anion-Exchange Column   Specifications
Maximum Operating Pressure:4000 psi (standard and microbore) 5000 psi (capillary)
Phase Compatibility:pH 0–14; 0–100% HPLC solvents
Ion Exchange Group:Functional Group: Alkanol quaternary ammonium ion
Column Construction:PEEK with 10–32 threaded ferrule style end fittings.
All components are nonmetallic.
Functional Group Characteristics:Ultralow Hydrophobicity
Dimensions:
IonPac AS20 Capillary Column:
0.4 ×250 mm 
IonPac AG20 Capillary Guard Column: 
0.4 × 50 mm 
IonPac AS20 Analytical Column:
2 × 250 mm
IonPac AG20 Guard Column:
2 × 50 mm
IonPac AS20 Analytical Column:
4 × 250 mm
IonPac AG20 Guard Column:
4 × 50 mm


Capacity:

3.1 ?eq (0.4 × 250 mm capillary column)
77.5 ?eq (2 × 250 mm analytical column)
310 ?eq (4 × 250 mm analytical column)
0.06 ?eq*(0.4 × 50 mm capillary guard column)
1.5 ?eq* (2 × 50 mm guard column)
6 ?eq* (4 × 50 mm guard column)
*Guards are packed with a low-capacity microporous resin.

Substrate Characteristics:Bead Diameter and Pore Size:
7.5 ?m (2 × 250, 4 × 250 and 0.4 × 250 mm);
super macroporous resin (2000 ?)
11 ?m (2 × 50, 4 × 50 and 0.4 × 50 mm);
microporous resin (<1 ?)
Crosslinking (%DVB): 55%



Analytical Columns
IonPac AS20 Analytical Column (2 x 250 mm)063065
IonPac AS20 Analytical Column (4 x 250 mm)063148
IonPac AS20 Capillary Column (0.4 x 250 mm)075399
Guard Columns
IonPac AG20 Guard Column (2 x 50 mm)063066
IonPac AG20 Guard Column (4 x 50 mm)063154
IonPac AG20 Capillary Guard Column (0.4 x 50 mm)075400

留言框

  • 產(chǎn)品:

  • 您的單位:

  • 您的姓名:

  • 聯(lián)系電話:

  • 常用郵箱:

  • 省份:

  • 詳細(xì)地址:

  • 補(bǔ)充說明:

  • 驗(yàn)證碼:

    請(qǐng)輸入計(jì)算結(jié)果(填寫阿拉伯?dāng)?shù)字),如:三加四=7