久久久影院,五月婷婷色77,久久亚洲电影精品,欧美另类一区二区三区在线

產(chǎn)品展示
PRODUCT DISPLAY

打印當(dāng)前頁(yè)

免費(fèi)咨詢:021-67610176

發(fā)郵件給我們:market@hsiyen.cn

分享到:
產(chǎn)品展示您現(xiàn)在的位置: 首頁(yè) > 產(chǎn)品展示 > > 美國(guó)戴安Dionex > 美國(guó)戴安 P/N: 043016Dionex IonPac CS10 Column 陽(yáng)離子交換柱

Dionex IonPac CS10 Column 陽(yáng)離子交換柱

簡(jiǎn)要描述:

戴安公司生產(chǎn)的儀器主要有離子色譜儀、高效液相色譜儀、快速溶劑萃取儀和氨基酸直接分析儀。其中離子色譜儀憑借著雄厚的技術(shù)優(yōu)勢(shì)和方法已廣泛地應(yīng)用于各個(gè)領(lǐng)域,其*達(dá)80%。與離子色譜相關(guān)的文章有90%均出自戴安公司生產(chǎn)的離子色譜儀。

型號(hào) 美國(guó)戴安 P/N: 043016
廠商性質(zhì) 代理商
更新日期 2018-04-22

IonPac CS10 Cation-Exchange Column

Sulfonate-Functionalized Cation-Exchange Column for Isocratic Separations Using HCl and DAP

The IonPac? CS10 is a sulfonate-functionalized cation-exchange column for the isocratic separation of inorganic cations using hydrochloric acid with diaminopropionic (DAP) acid eluents. The CS12A is the recommended column for the fast analysis of inorganic cations; the CS17, for hydrophobic and polyvalent amines; and the CS18, for polar amines. The CS18 is also recommended for moderay hydrophobic and polyvalent amines.

  • The CS10 can be used for analysis of the common inorganic cations and aliphatic, cyclic, and aromatic amines.
  • Compatible with organic solvents.
  • The CS12A provides improved performance for fast analysis of inorganic cations and ammonium.
  • The CS17 column is recommended for hydrophobic and polyvalent amines.
  • The CS18 column is recommended for polar amines including alkanolamines and methylamines.
  • The CS18 is also recommended for moderay hydrophobic amines and polyvalent amines.

The IonPac CS10 is designed for the isocratic separation of lithium, sodium, ammonium, potassium, magnesium, and calcium using hydrochloric acid with diaminopropionic acid eluents with suppressed conductivity detection. Sample matrices for the CS10 include environmental waters; power plant waters treated wtih ammonium, morpholine, or ethanolamine; chemical additives; chemical process solutions; scrubber solutions; plating baths; and industrial solvents.

The CS11 has selectvitity similar to the CS10 column, with improved sensitivity due to its smaller 2 mm i.d. format.

Note: Use the Cation MicroMembrane Suppressor (CMMS? 300) with the CS10 column. Electrolytic suppression is not recommended with HCl and DAP eluents.

IonPac CS10 Cation-Exchange Column  Specifications
DimensionsIonPac CS10 Analytical Column:
4 × 250 mm
IonPac CG10 Guard Column:
4 × 50 mm
Maximum operating pressure4000 psi (27.5 MPa)
phase compatibilitypH 0–14; 0–100% HPLC solvents (i.e., methanol, acetonitrile).
Resin characteristics8.5 ?m ethylvinylbenzene/divinylbenzene substrate agglomerated with 200-nm MicroBead?cation-exchange latex
Latex characteristicsIon-Exchange Group: Sulfonic acid Latex
Cross-Linking: 5%
Latex Diameter: 200 nm
Hyrophobicity: Medium
Capacity80 ?eq (4 × 250 mm analytical column)
Column constructionPEEK with 10-32 threaded ferrule-style end fittings.
All components are nonmetallic.



Analytical Columns
IonPac CS10 Analytical Column (4 x 250 mm)043015
Guard Columns
IonPac CG10 Guard Column (4 x 50 mm)043016


留言框

  • 產(chǎn)品:

  • 您的單位:

  • 您的姓名:

  • 聯(lián)系電話:

  • 常用郵箱:

  • 省份:

  • 詳細(xì)地址:

  • 補(bǔ)充說(shuō)明:

  • 驗(yàn)證碼:

    請(qǐng)輸入計(jì)算結(jié)果(填寫(xiě)阿拉伯?dāng)?shù)字),如:三加四=7