戴安公司生產(chǎn)的儀器主要有離子色譜儀、高效液相色譜儀、快速溶劑萃取儀和氨基酸直接分析儀。其中離子色譜儀憑借著雄厚的技術(shù)優(yōu)勢和方法已廣泛地應(yīng)用于各個領(lǐng)域,其*達(dá)80%。與離子色譜相關(guān)的文章有90%均出自戴安公司生產(chǎn)的離子色譜儀。
型號 | 美國戴安 P/N: 046075 |
---|---|
廠商性質(zhì) | 代理商 |
更新日期 | 2018-04-21 |
The IonPac? CS12A is a medium-capacity, carboxylate-functionalized cation-exchange column recommended for fast, isocratic separation of lithium, sodium, ammonium, potassium, magnesium, and calcium using methanesulfonic or sulfuric acid eluents in diverse sample matrices.
The new CS12A-8μm and CS12A-5μm Capillary Columns offer the same selectivity as their analytical-scale counterparts, but offer the advantage of reduced eluent consumption, thereby lowering operating costs.
The medium-capacity IonPac CS12A cation-exchange column supports fast, isocratic separation with suppressed conductivity detection. Sample matrices include environmental and drinking waters; soil extracts; acid digests; power plant waters treated with ammonium or morpholine; chemical additives; chemical process solutions; scrubber solutions; plating baths; and industrial solvents.
Use the CS12A-5μm columns for high efficiency and fast analysis (4 min). The smaller-diameter resin technology and reduced column length provide faster analysis time, reduced eluent consumption, and increased sensitivity. The CS12A column is the recommended replacement for all CS12 applications. Use the CS12A column with the Eluent Generator for simplified methanesulfonic acid eluent preparation.
IonPac CS12A Cation-Exchange Column Specifications | |
---|---|
Dimensions | IonPac CS12A Analytical Column: 2 × 250 mm, 3 × 150 mm, and 4 × 250 mm IonPac CG12A Guard Column: 2 × 50 mm, 3 × 30 mm, and 4 × 50 mm IonPac CS12A Capillary Column: 0.4 × 250 mm and 0.4 × 150 mm IonPac CG12A Capillary Guard Column: 0.4 × 50 mm |
Maximum operating pressure | 4000 psi (standard and microbore) 5000 psi (capillary) |
phase compatibility | Acidic eluents; 0–100% acetonitrile. Alcohols should be avoided. |
Substrate characteristics | Bead Diameter: 8 μm (0.4 x 250, 2 x 100, 2 x 250 and 4 x 250 mm), 5 μm (0.4 x 150 and 3 x 150 mm) Cross-Linking (%DVB): 55% |
Functional group characteristics | Ion-Exchange Groups: Grafted carboxylic acid and phosphonic acid Surface Characteristics: Medium hydrophilic |
Capacity | 28 μeq (0.4 × 250 mm capillary column) 9.4 μeq (0.4 × 150 mm capillary column) 280 μeq (2 × 100 mm analytical column) 700 μeq (2 × 250 mm analytical column) 940 μeq (3 × 150 mm analytical column) 2800 μeq (4 × 250 mm analytical column) |
Column construction | PEEK with 10-32 threaded ferrule-style end fittings. All components are nonmetallic. |
Analytical Columns | |
---|---|
IonPac CS12A Analytical Column (4 x 250 mm) | 046073 |
IonPac CS12A Analytical Column (2 x 250 mm) | 046075 |
IonPac CS12A-5 μm Analytical Column (3 x 150 mm) | 057185 |
IonPac CS12A-MS (2 x 100 mm) Column | 059960 |
IonPac CS12A-8μm Capillary Column (0.4 x 250 mm) | 079914 |
IonPac CS12A-5μm Capillary Column (0.4 x 150 mm) | 072068 |
Guard Columns | |
---|---|
IonPac CG12A-5 μm Guard Column (3 x 30 mm) | 057184 |
IonPac CG12A Guard Column (2 x 50 mm) | 046076 |
IonPac CG12A Guard Column (4 x 50 mm) | 046074 |
IonPac CG12A-8μm Capillary Guard Column (0.4 x 50 mm) | 072067 |
IonPac CG12A-5μm Capillary Guard Column (0.4 x 50 mm) | 072069 |