戴安公司生產(chǎn)的儀器主要有離子色譜儀、高效液相色譜儀、快速溶劑萃取儀和氨基酸直接分析儀。其中離子色譜儀憑借著雄厚的技術(shù)優(yōu)勢(shì)和方法已廣泛地應(yīng)用于各個(gè)領(lǐng)域,其*達(dá)80%。與離子色譜相關(guān)的文章有90%均出自戴安公司生產(chǎn)的離子色譜儀。 戴安公司的快速溶劑萃取儀15分鐘之內(nèi)僅用15毫升溶劑既可完成對(duì)10g樣品的萃取,該技術(shù)已在環(huán)境、藥物、食品和聚合物工業(yè)等領(lǐng)域得到廣泛應(yīng)用。
型號(hào) | SP5727 |
---|---|
廠商性質(zhì) | 代理商 |
更新日期 | 2017-11-10 |
Dionex ProPac SCX and WCX Protein Column
New! The Thermo Scientific ProPac™ SCX column line has expanded to include the next generation ProPac SCX-20 column. This column provides unequalled high resolution of protein variants.
Please also see the Thermo Scientific MAbPac™ SCX-10 column, a strong cation-exchange column designed specifically for high-resolution, high-efficiency analysis of monoclonal antibodies (MAbs) and associated variants. This column is complimentary to the industry-leading ProPac WCX-10 column for monoclonal antibody variant analysis. The MAbPac SCX-10 offers an alternative selectivity and provides higher resolution and efficiency for variant analysis of most monoclonal antibody samples than the ProPac WCX-10 column.
ProPac SCX-10 and WCX-10 strong and weak cation-exchange columns are based on a nonporous core particle that results in high-efficiency peaks and high-resolution separations of protein variants. A hydrophilic layer prevents unwanted secondary interactions. A grafted cation-exchange surface provides pH-based selectivity control and fast mass transfer for high-efficiency separation and moderate capacity.
The ProPac SCX-10 is a strong cation-exchange column with sulfonate functional groups, and the ProPac WCX-10 column has a carboxylate functional group. Both are based on 10 ?m nonporous, polymeric beads and coated with a proprietary hydrophilic layer.
All ProPac columns are manufactured and tested under the strictest specifications, resulting in unmatched column-to-column and lot-to-lot reproducibility. These columns are available as lot-select packages containing three columns from a single lot or three columns from three different lots, to assist quality control scientists in method validation.
ProPac SCX-10 Strong Cation-Exchange Column for the High-Resolution Separation of Protein Isoforms Specifications | |
---|---|
Maximum operating pressure | 3000 psi (21 MPa) |
Maximum operating temperature | 60 °C Recommended operating temperature: <40 °C |
Typical operating conditions | UV detection at 1 mL/min Recommended flow rate: 1 mL/min |
phase compatibility | pH 2–12; 80% compatible with acetonitrile, acetone, methanol. Compatible with nonionic and zwitterionic detergents. Incompatible with cationic detergents. |
Resin composition | 10-?m-diameter core bead (55% cross-linked) grafted with a pellicular layer to which are attached the sulfonate functional groups. |
Anion-exchange capacity | < 100 ?g protein on-column, depending upon the protein (4 × 250 mm analytical column) |
Column construction | PEEK with 10-32 threaded ferrule-style end fittings. All components are nonmetallic. |
ProPac WCX-10 Weak Cation-Exchange Column for the High-Resolution Separation of Protein Isoforms Specifications | |
---|---|
Resin composition | 10-?m-diameter core bead (55% cross-linked) grafted with a pellicular layer to which are attached the carboxylate functional groups. |
Anion-exchange capacity | < 100 ?g protein on-column, depending upon the protein (4 × 250 mm analytical column) |
Column construction | PEEK with 10-32 threaded ferrule-style end fittings. All components are nonmetallic. |
Maximum operating pressure | 3000 psi (21 MPa) |
Maximum operating temperature | 60 °C Recommended operating temperature: <40 °C |
Typical operating conditions | UV detection at 1 mL/min Recommended flow rate: 1 mL/min |
phase compatibility | pH 2–12; 80% compatible with acetonitrile and acetone. Compatible with nonionic and zwitterionic detergents. Incompatible with cationic detergents. |
SCX Analytical Columns | |
---|---|
ProPac SCX-20 Analytical Column (4 x 250 mm) | 074628 |
ProPac SCX-10 Analytical Column (4 x 250 mm) | 054995 |
ProPac SCX-10 Analytical Column (2 x 250 mm) | 063456 |
ProPac SCX-10 Semi-Preparative Column (9 x 250 mm) | 063700 |
ProPac SCX-10 Semi-Preparative Column (22 x 250 mm) | SP5522 |
ProPac SCX-10 Lot Select Column Set (4 x 250 mm) (1 Lot of Resin) | SP5727 |
ProPac SCX-10 Lot Select Column Set (4 x 250 mm) (3 Lots of Resin) | SP5728 |
SCX Guard Columns | |
---|---|
ProPac SCX-20 Guard Column (4 x 50mm) | 074643 |
ProPac SCX-10G Guard Column (4 x 50 mm) | 079930 |
ProPac SCX-10G Guard Column (2 x 50 mm) | 063462 |
WCX Analytical Columns | |
---|---|
ProPac WCX-10HT Analytical Column (4x 50mm) | 074600 |
ProPac WCX-10 Analytical Column (4 x 100 mm) | SP5829 |
ProPac WCX-10 Analytical Column (4 x 150 mm) | SP6703 |
ProPac WCX-10 Analytical Column (4 x 250 mm) | 054993 |
ProPac WCX-10 Lot Select 3 Column Set (4 x 250 mm) (1 Lot of Resin) | SP5512 |
ProPac WCX-10 Lot Select 3 Column Set (4 x 250 mm) (3 Lots of Resin) | SP5513 |
ProPac WCX-10 Analytical Column (2 x 250 mm) | 063472 |
ProPac WCX-10 Semi-Preparative Column (9 x 250 mm) | 063474 |
ProPac WCX-10 Semi-Preparative Column (22 x 250 mm) | SP5482 |
WCX Guard Columns | |
---|---|
ProPac WCX-10G Guard Column (2 x 50 mm) | 063480 |
ProPac WCX-10G Guard Column (4 x 50 mm) | 054994 |